Independent directory Public ClinicalTrials.gov records United States
ClinicalTrials.gov record
Completed Not applicable Interventional

Water-aided Colonoscopy vs Air Insufflation Colonoscopy in Colorectal Cancer Screening

ClinicalTrials.gov ID: NCT02041507

Public ClinicalTrials.gov record NCT02041507. Field values are reproduced from the official study page; the official ClinicalTrials.gov record remains the source of truth for eligibility, enrollment, and contact information.

ClinicalTrials.gov public records Last synced Sep 5, 2026, 12:14 PM EDT

Data is sourced from official ClinicalTrials.gov public API records. Always review the official ClinicalTrials.gov record for the latest information.

Official title

A Randomized, Controlled Trial Comparing Air Insufflation, Water Immersion and Water Exchange for Adenoma Detection Rate in Screening Colonoscopy

Brief summary

Reproduced verbatim from the official ClinicalTrials.gov record. Not medical advice.

The degree of protection afforded by colonoscopy against proximal colorectal cancer (CRC) appears to be related to the quality of the procedure, and the incomplete removal of lesions has been shown to increase the subsequent risk of developing a colon cancer. Some studies suggest that small polyps with advanced histology are more common in the right than in the left colon (right colon proximal to splenic flexure, left colon distal to the splenic flexure). The average size of polyps in the right colon with advanced pathology or containing adenocarcinoma was ≤9 mm, whereas in the left colon their average size was \>9 mm, P\<0.001. Inadequate prevention of right-sided CRC incidence and mortality may be due to right-sided polyps with advanced histology or that harbor malignancy. These presumptive precursors of cancer are smaller and possibly more easily obscured by residual feces, and more likely to be missed at colonoscopy. Water-aided colonoscopy (WAC) can be subdivided broadly into two major categories: water immersion (WI), characterized by suction removal of the infused water predominantly during the withdrawal phase of colonoscopy, and water exchange (WE), characterized by suction removal of infused water predominantly during the insertion phase of colonoscopy. In some reports WE appeared to be superior to both WI and air insufflation colonoscopy (AI) in terms of pain reduction and adenoma detection, particularly for \<10 mm adenomas in the proximal colon. In this multicenter, double-blinded randomized controlled trial (RCT) we test the hypothesis that that WE, compared to AI and WI, will enhance overall Adenoma Detection Rate (ADR) in CRC screening patients. Confirmation of the primary hypothesis will provide evidence that WE enhances the quality of screening colonoscopy. We also hypothesize that WE may be more effective in detecting proximal colon adenomas than WI and AI, particularly \<10 mm adenomas, thus increasing proximal colon ADR and proximal colon ADR \<10 mm. Confirmation of secondary hypotheses will provide justification for further testing that WE may provide a strategy to improve prevention of colorectal cancer by increasing detection of adenomas in screening colonoscopy. Unlike previous reports of single colonoscopist studies, the insertion and withdrawal phases of colonoscopy will be done by different investigators. The second investigator will be blinded to the method used to insert the instrument, thus eliminating possible bias about procedure related issues. Several secondary outcomes will also be analysed.

Study identification

NCT ID
NCT02041507
Recruitment status
Completed
Study type
Interventional
Phase
Not applicable
Enrollment
1,224 participants

Conditions and interventions

Eligibility (public fields only)

Age range
50 Years to 70 Years
Sex
All
Healthy volunteers
Healthy volunteers not accepted

This page does not interpret eligibility. Detailed inclusion and exclusion criteria are on the official ClinicalTrials.gov record.

Study timeline

Start date
Jan 31, 2014
Primary completion
Feb 29, 2016
Completion
Mar 31, 2016
Last update posted
Apr 12, 2016

2014 – 2016

United States locations

U.S. sites
1
U.S. states
1
U.S. cities
1
Facility City State ZIP Site status
Sepulveda Ambulatory Care Center, VA Greater Los Angeles Healthcare System Los Angeles California 91343

Site contact phone numbers, emails, and investigator names are intentionally not displayed here. Open the official ClinicalTrials.gov record for site contact information.

Non-U.S. locations

This page focuses on the U.S. directory. The official record also lists 3 non-U.S. sites.

About this trial record page

What this page shows
Public field values for ClinicalTrials.gov record NCT02041507, including study identification, conditions, interventions, eligibility (age, sex, healthy volunteer), timeline, and U.S. site list.
What this page does not do
No medical advice, eligibility judgments, treatment recommendations, study quality scoring, or AI-generated medical summaries. No site contact phone numbers, emails, or investigator names.
Where the data comes from
Sourced from the official ClinicalTrials.gov public API. The official record is the source of truth.
Last refresh
Last update posted Apr 12, 2016 · Synced Sep 5, 2026

Related: full search, browse by condition, browse by drug or therapy, browse by sponsor, browse by U.S. city.

Open the official record

The complete protocol, eligibility criteria, and contact information for NCT02041507 live on ClinicalTrials.gov.

View official ClinicalTrials.gov record →